Other findings
- Automatic shutdown behaviour
- 7 days above 20%, 24 hours below
- Bluetooth monitoring
- Bluetooth via Epoch's LI-ION app, with OTA updates
- Charging when powered down
- It will not charge until switched on
- Power down threshold
- Any cell under 2.2 V, or the pack near 38 V
- Restart procedure
- Two presses, not one
“Automatic Shutdown 1. If the SOC of the battery pack is higher than 20% and there is no discharging for 7 days, it will automatically shut down. 2. If the SOC of battery pack is equal or less than 20% and there is no discharging for 24 hours, it will automatically shut down as well. In automatic shutdown state, press the ON-OFF switch twice to restart the battery.”
Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B51100A_Lithium_Battery_User_Manual_2024-4-19.pdf?v=1714369601
“EPOCH LI-ION ". For example, you can monitor the battery' real- time SOC, SOH, Capacity, Voltage, Current, Temperature, Warning on this APP. You can also upgrade battery' program by the OTA function on this APP.”
Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B51100A_Lithium_Battery_User_Manual_2024-4-19.pdf?v=1714369601
“Power down When single battery cell voltage is lower than 2.2V or the total voltage of the battery pack is about 38V, the battery is in power-down state. In the power-down state, please press the ON-OFF switch to power on the battery and charge it with a charger immediately. In the power-down state, you can only charge it after you turn on the switch.”
Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B51100A_Lithium_Battery_User_Manual_2024-4-19.pdf?v=1714369601
“Power down When single battery cell voltage is lower than 2.2V or the total voltage of the battery pack is about 38V, the battery is in power-down state. In the power-down state, please press the ON-OFF switch to power on the battery and charge it with a charger immediately. In the power-down state, you can only charge it after you turn on the switch.”
Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B51100A_Lithium_Battery_User_Manual_2024-4-19.pdf?v=1714369601
“Automatic Shutdown 1. If the SOC of the battery pack is higher than 20% and there is no discharging for 7 days, it will automatically shut down. 2. If the SOC of battery pack is equal or less than 20% and there is no discharging for 24 hours, it will automatically shut down as well. In automatic shutdown state, press the ON-OFF switch twice to restart the battery.”
Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B51100A_Lithium_Battery_User_Manual_2024-4-19.pdf?v=1714369601
Sources
- Archived document
Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B51100A_Lithium_Battery_User_Manual_2024-4-19.pdf?v=1714369601
Retrieved September 21, 2026