Motor and performance

Controller continuous current (battery amps)
125

“Model 2 Min (Amps) 5 Min (Amps) Continuous (Amps) NCT48275 275 175 125 XCT48300 300 200 125 XCT48400 400 250 140 XCT48500 500 400 250”

Source: ddmotorsystems.com/DOC113-006-C_OP-XCT-OPERATORS-MANUAL.pdf

Motor type it drives
Shunt Motor Controller

“Type: Shunt Motor Controller Operating Frequency: 18kHz”

Source: ddmotorsystems.com/DOC113-006-C_OP-XCT-OPERATORS-MANUAL.pdf

Operating temperature range
Operating Temperature: -20°C to 85°C, shutdown @ 95°C

“Operating Temperature: -20°C to 85°C, shutdown @ 95°C”

Source: ddmotorsystems.com/DOC113-006-C_OP-XCT-OPERATORS-MANUAL.pdf

Sources

  • Archived document

    Source: ddmotorsystems.com/DOC113-006-C_OP-XCT-OPERATORS-MANUAL.pdf