Identity
- Type
- Solenoid
- Maker printed on the part
- Albright International
- Maker part number
- DC182
Motor and performance
- Fault breaking capacity at 5 ms, no blowouts
- 1000A at 48V D.C.
- Intermittent current at 30% duty (interrupted)
- 275A interrupted at 30% duty
- Intermittent current at 30% duty (uninterrupted)
- 275A uninterrupted at 30% duty
- Intermittent current at 40% duty (interrupted)
- 235A interrupted at 40% duty
- Intermittent current at 40% duty (uninterrupted)
- 235A uninterrupted at 40% duty
- Intermittent current at 50% duty (interrupted)
- 210A interrupted at 50% duty
- Intermittent current at 50% duty (uninterrupted)
- 210A uninterrupted at 50% duty
- Intermittent current at 60% duty (interrupted)
- 195A interrupted at 60% duty
- Intermittent current at 60% duty (uninterrupted)
- 195A uninterrupted at 60% duty
- Intermittent current at 70% duty (interrupted)
- 180A interrupted at 70% duty
- Intermittent current at 70% duty (uninterrupted)
- 180A uninterrupted at 70% duty
- Fault breaking capacity at 5 ms, with blowouts
- 1000A at 96V D.C.
“(In accordance with UL583*) Blowouts 1000A at 96V D.C. No Blowouts 1000A at 48V D.C.”
Source: albrightinternational.com/products/dc182
“30% Duty 275A 275A”
Source: albrightinternational.com/products/dc182
“30% Duty 275A 275A”
Source: albrightinternational.com/products/dc182
“40% Duty 235A 235A”
Source: albrightinternational.com/products/dc182
“40% Duty 235A 235A”
Source: albrightinternational.com/products/dc182
“50% Duty 210A 210A”
Source: albrightinternational.com/products/dc182
“50% Duty 210A 210A”
Source: albrightinternational.com/products/dc182
“60% Duty 195A 195A”
Source: albrightinternational.com/products/dc182
“60% Duty 195A 195A”
Source: albrightinternational.com/products/dc182
“70% Duty 180A 180A”
Source: albrightinternational.com/products/dc182
“70% Duty 180A 180A”
Source: albrightinternational.com/products/dc182
“(In accordance with UL583*) Blowouts 1000A at 96V D.C. No Blowouts 1000A at 48V D.C.”
Source: albrightinternational.com/products/dc182
Compatibility
- What the maker says it is for
- motors as used on electric vehicles such as industrial trucks and airport
“particularly motors as used on electric vehicles such as industrial trucks and airport tractors.”
Source: albrightinternational.com/products/dc182
Frame and components
- Part type
- D.C. contactor
“DC182 motor reversing D.C. contactor - Albright”
Source: albrightinternational.com/products/dc182
Identity
- Manufacturer of record
- Albright
- Model code
- DC182
“DC182 motor reversing D.C. contactor - Albright”
Source: albrightinternational.com/products/dc182
“DC182 motor reversing D.C. contactor - Albright”
Source: albrightinternational.com/products/dc182
Other findings
- Coil voltage range
- 6 - 240V (rectifier board required for A.C.)
- Contact arrangement
- double breaking main contacts with silver alloy contact tips
- Failsafe
- open circuit if both coils energised
- Max contact voltage no blowouts interrupted
- 48V
- Max contact voltage with blowouts interrupted
- 96V
- Mechanical durability
- > 5,000,000 Cycles
- Thermal current rating interrupted
- 150A interrupted
- Thermal current rating uninterrupted
- 150A uninterrupted
- Voltage drop per pole
- 40mV at 150A
“Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V”
Source: albrightinternational.com/products/dc182
“The DC182 has double breaking main contacts with silver alloy contact tips”
Source: albrightinternational.com/products/dc182
“if both coils are energised simultaneously the contact arrangement is open circuits.”
Source: albrightinternational.com/products/dc182
“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”
Source: albrightinternational.com/products/dc182
“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”
Source: albrightinternational.com/products/dc182
“Mechanical Durability > 5,000,000 Cycles”
Source: albrightinternational.com/products/dc182
“Thermal Current Rating 150A 150A”
Source: albrightinternational.com/products/dc182
“Thermal Current Rating 150A 150A”
Source: albrightinternational.com/products/dc182
“Typical Voltage Drop per pole across New Contacts at 150A 40mV”
Source: albrightinternational.com/products/dc182