Albright International DC182

Albright International's product page

Identity

Type
Solenoid
Maker printed on the part
Albright International
Maker part number
DC182

Motor and performance

Fault breaking capacity at 5 ms, no blowouts
1000A at 48V D.C.

“(In accordance with UL583*) Blowouts 1000A at 96V D.C. No Blowouts 1000A at 48V D.C.”

Source: albrightinternational.com/products/dc182

Intermittent current at 30% duty (interrupted)
275A interrupted at 30% duty

“30% Duty 275A 275A”

Source: albrightinternational.com/products/dc182

Intermittent current at 30% duty (uninterrupted)
275A uninterrupted at 30% duty

“30% Duty 275A 275A”

Source: albrightinternational.com/products/dc182

Intermittent current at 40% duty (interrupted)
235A interrupted at 40% duty

“40% Duty 235A 235A”

Source: albrightinternational.com/products/dc182

Intermittent current at 40% duty (uninterrupted)
235A uninterrupted at 40% duty

“40% Duty 235A 235A”

Source: albrightinternational.com/products/dc182

Intermittent current at 50% duty (interrupted)
210A interrupted at 50% duty

“50% Duty 210A 210A”

Source: albrightinternational.com/products/dc182

Intermittent current at 50% duty (uninterrupted)
210A uninterrupted at 50% duty

“50% Duty 210A 210A”

Source: albrightinternational.com/products/dc182

Intermittent current at 60% duty (interrupted)
195A interrupted at 60% duty

“60% Duty 195A 195A”

Source: albrightinternational.com/products/dc182

Intermittent current at 60% duty (uninterrupted)
195A uninterrupted at 60% duty

“60% Duty 195A 195A”

Source: albrightinternational.com/products/dc182

Intermittent current at 70% duty (interrupted)
180A interrupted at 70% duty

“70% Duty 180A 180A”

Source: albrightinternational.com/products/dc182

Intermittent current at 70% duty (uninterrupted)
180A uninterrupted at 70% duty

“70% Duty 180A 180A”

Source: albrightinternational.com/products/dc182

Fault breaking capacity at 5 ms, with blowouts
1000A at 96V D.C.

“(In accordance with UL583*) Blowouts 1000A at 96V D.C. No Blowouts 1000A at 48V D.C.”

Source: albrightinternational.com/products/dc182

Compatibility

What the maker says it is for
motors as used on electric vehicles such as industrial trucks and airport

“particularly motors as used on electric vehicles such as industrial trucks and airport tractors.”

Source: albrightinternational.com/products/dc182

Frame and components

Part type
D.C. contactor

“DC182 motor reversing D.C. contactor - Albright”

Source: albrightinternational.com/products/dc182

Identity

Manufacturer of record
Albright

“DC182 motor reversing D.C. contactor - Albright”

Source: albrightinternational.com/products/dc182

Model code
DC182

“DC182 motor reversing D.C. contactor - Albright”

Source: albrightinternational.com/products/dc182

Other findings

Coil voltage range
6 - 240V (rectifier board required for A.C.)

“Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V”

Source: albrightinternational.com/products/dc182

Contact arrangement
double breaking main contacts with silver alloy contact tips

“The DC182 has double breaking main contacts with silver alloy contact tips”

Source: albrightinternational.com/products/dc182

Failsafe
open circuit if both coils energised

“if both coils are energised simultaneously the contact arrangement is open circuits.”

Source: albrightinternational.com/products/dc182

Max contact voltage no blowouts interrupted
48V

“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”

Source: albrightinternational.com/products/dc182

Max contact voltage with blowouts interrupted
96V

“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”

Source: albrightinternational.com/products/dc182

Mechanical durability
> 5,000,000 Cycles

“Mechanical Durability > 5,000,000 Cycles”

Source: albrightinternational.com/products/dc182

Thermal current rating interrupted
150A interrupted

“Thermal Current Rating 150A 150A”

Source: albrightinternational.com/products/dc182

Thermal current rating uninterrupted
150A uninterrupted

“Thermal Current Rating 150A 150A”

Source: albrightinternational.com/products/dc182

Voltage drop per pole
40mV at 150A

“Typical Voltage Drop per pole across New Contacts at 150A 40mV”

Source: albrightinternational.com/products/dc182