Albright International DC88

Identity

Type
Solenoid
Maker printed on the part
Albright International
Maker part number
DC88

Compatibility

What the maker says it is for
motors as used on electric vehicles such as industrial trucks

“has been designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks.”

Source: albrightinternational.com/products/dc88

Other findings

Coil voltage range
6 - 240V (rectifier board required for A.C.)

“Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V”

Source: albrightinternational.com/products/dc88

Contact arrangement
double breaking main contacts with silver alloy contact tips

“The DC88 has double breaking main contacts with silver alloy contact tips”

Source: albrightinternational.com/products/dc88

Failsafe
if both coils are energised simultaneously the contact arrangement is open

“if both coils are energised simultaneously the contact arrangement is open circuit”

Source: albrightinternational.com/products/dc88

Fault breaking capacity 5ms no blowouts
800A at 48V D.C.

“(In accordance with UL583*) Blowouts 600A at 80V D.C. No Blowouts 800A at 48V D.C.”

Source: albrightinternational.com/products/dc88

Fault breaking capacity 5ms with blowouts
600A at 80V D.C.

“(In accordance with UL583*) Blowouts 600A at 80V D.C. No Blowouts 800A at 48V D.C.”

Source: albrightinternational.com/products/dc88

Intermittent current 30 duty interrupted
185A interrupted at 30% duty

“30% Duty 185A 185A”

Source: albrightinternational.com/products/dc88

Intermittent current 30 duty uninterrupted
185A uninterrupted at 30% duty

“30% Duty 185A 185A”

Source: albrightinternational.com/products/dc88

Intermittent current 40 duty interrupted
160A interrupted at 40% duty

“40% Duty 160A 160A”

Source: albrightinternational.com/products/dc88

Intermittent current 40 duty uninterrupted
160A uninterrupted at 40% duty

“40% Duty 160A 160A”

Source: albrightinternational.com/products/dc88

Intermittent current 50 duty interrupted
140A interrupted at 50% duty

“50% Duty 140A 140A”

Source: albrightinternational.com/products/dc88

Intermittent current 50 duty uninterrupted
140A uninterrupted at 50% duty

“50% Duty 140A 140A”

Source: albrightinternational.com/products/dc88

Intermittent current 60 duty interrupted
130A interrupted at 60% duty

“60% Duty 130A 130A”

Source: albrightinternational.com/products/dc88

Intermittent current 60 duty uninterrupted
130A uninterrupted at 60% duty

“60% Duty 130A 130A”

Source: albrightinternational.com/products/dc88

Intermittent current 70 duty interrupted
120A interrupted at 70% duty

“70% Duty 120A 120A”

Source: albrightinternational.com/products/dc88

Intermittent current 70 duty uninterrupted
120A uninterrupted at 70% duty

“70% Duty 120A 120A”

Source: albrightinternational.com/products/dc88

Main terminals
M8 main stud terminals

“The DC88 M8 main stud terminals”

Source: albrightinternational.com/products/dc88

Max contact voltage no blowouts interrupted
48V

“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 48V”

Source: albrightinternational.com/products/dc88

Max contact voltage no blowouts uninterrupted
48V

“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 48V”

Source: albrightinternational.com/products/dc88

Max contact voltage with blowouts interrupted
96V

“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 48V”

Source: albrightinternational.com/products/dc88

Max contact voltage with blowouts uninterrupted
96V

“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 48V”

Source: albrightinternational.com/products/dc88

Mechanical durability
> 5,000,000 Cycles

“Mechanical Durability > 5,000,000 Cycles”

Source: albrightinternational.com/products/dc88

Thermal current rating interrupted
100A interrupted

“Thermal Current Rating 100A 100A”

Source: albrightinternational.com/products/dc88

Thermal current rating uninterrupted
100A uninterrupted

“Thermal Current Rating 100A 100A”

Source: albrightinternational.com/products/dc88

Voltage drop per pole
50mV at 100A

“Typical Voltage Drop per pole across New Contacts at 100A 50mV”

Source: albrightinternational.com/products/dc88