Albright International SW200
Solenoid
Identity
- Type
- Solenoid
- Maker printed on the part
- Albright International
- Maker part number
- SW200
Compatibility
- What the maker says it is for
- direct current loads, including motors as used on electric vehicles such as industrial trucks
“The SW200 has been designed for direct current loads, including motors as used on electric vehicles such as industrial trucks.”
Source: albrightinternational.com/products/sw200
Other findings
- Coil connections
- 6.3mm spade coil connections
- Coil voltage range
- 6 - 240V (rectifier board required for A.C.)
- Contact arrangement
- single pole single throw, double breaking main contacts with silver alloy tips
- Fault breaking capacity 5ms no blowouts
- 1500A at 48V D.C.
- Fault breaking capacity 5ms with blowouts
- 1500A at 96V D.C.
- Fault breaking capacity resistive no blowouts
- 600A at 60V D.C.
- Fault breaking capacity resistive with blowouts
- 600A at 96V D.C.
- Intermittent current 30 duty interrupted
- 455A interrupted at 30% duty
- Intermittent current 30 duty uninterrupted
- 730A uninterrupted at 30% duty
- Intermittent current 40 duty interrupted
- 395A interrupted at 40% duty
- Intermittent current 40 duty uninterrupted
- 630A uninterrupted at 40% duty
- Intermittent current 50 duty interrupted
- 355A interrupted at 50% duty
- Intermittent current 50 duty uninterrupted
- 565A uninterrupted at 50% duty
- Intermittent current 60 duty interrupted
- 325A interrupted at 60% duty
- Intermittent current 60 duty uninterrupted
- 515A uninterrupted at 60% duty
- Intermittent current 70 duty interrupted
- 300A interrupted at 70% duty
- Intermittent current 70 duty uninterrupted
- 480A uninterrupted at 70% duty
- Main terminals
- M10 stud main terminals
- Max contact voltage no blowouts interrupted
- 48V
- Max contact voltage no blowouts uninterrupted
- 60V
- Max contact voltage with blowouts interrupted
- 96V
- Max contact voltage with blowouts uninterrupted
- 96V
- Mechanical durability
- > 5,000,000 Cycles
- Mounting tapped holes
- M5 tapped holes or mounting brackets
- Thermal current rating interrupted
- 250A interrupted
- Thermal current rating uninterrupted
- 400A uninterrupted
- Voltage drop per pole
- 40mV at 250A
“The SW200 has M10 stud main terminals and 6.3mm spade coil connections.”
Source: albrightinternational.com/products/sw200
“Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V”
Source: albrightinternational.com/products/sw200
“The SW200 features single pole single throw, double breaking main contacts with silver alloy tips”
Source: albrightinternational.com/products/sw200
“(In accordance with UL583*) Blowouts 1500A at 96V D.C. No Blowouts 1500A at 48V D.C.”
Source: albrightinternational.com/products/sw200
“(In accordance with UL583*) Blowouts 1500A at 96V D.C. No Blowouts 1500A at 48V D.C.”
Source: albrightinternational.com/products/sw200
“(In accordance with UL508*) Blowouts 600A at 96V D.C. No Blowouts 600A at 60V D.C.”
Source: albrightinternational.com/products/sw200
“(In accordance with UL508*) Blowouts 600A at 96V D.C. No Blowouts 600A at 60V D.C.”
Source: albrightinternational.com/products/sw200
“30% Duty 455A 730A”
Source: albrightinternational.com/products/sw200
“30% Duty 455A 730A”
Source: albrightinternational.com/products/sw200
“40% Duty 395A 630A”
Source: albrightinternational.com/products/sw200
“40% Duty 395A 630A”
Source: albrightinternational.com/products/sw200
“50% Duty 355A 565A”
Source: albrightinternational.com/products/sw200
“50% Duty 355A 565A”
Source: albrightinternational.com/products/sw200
“60% Duty 325A 515A”
Source: albrightinternational.com/products/sw200
“60% Duty 325A 515A”
Source: albrightinternational.com/products/sw200
“70% Duty 300A 480A”
Source: albrightinternational.com/products/sw200
“70% Duty 300A 480A”
Source: albrightinternational.com/products/sw200
“The SW200 has M10 stud main terminals and 6.3mm spade coil connections.”
Source: albrightinternational.com/products/sw200
“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 60V”
Source: albrightinternational.com/products/sw200
“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 60V”
Source: albrightinternational.com/products/sw200
“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 60V”
Source: albrightinternational.com/products/sw200
“Maximum Recommended Contact Voltages Blowouts 96V 96V No Blowouts 48V 60V”
Source: albrightinternational.com/products/sw200
“Mechanical Durability > 5,000,000 Cycles”
Source: albrightinternational.com/products/sw200
“It can be mounted via M5 tapped holes or mounting brackets”
Source: albrightinternational.com/products/sw200
“Thermal Current Rating 250A 400A”
Source: albrightinternational.com/products/sw200
“Thermal Current Rating 250A 400A”
Source: albrightinternational.com/products/sw200
“Typical Voltage Drop per pole across New Contacts at 250A 40mV”
Source: albrightinternational.com/products/sw200
Models documented with this part