Identity
- Type
- Solenoid
- Maker printed on the part
- Albright International
- Maker part number
- SW202
Motor and performance
- Fault breaking capacity at 5 ms, no blowouts
- 1500A at 48V D.C.
- Intermittent current at 30% duty (interrupted)
- 455A interrupted at 30% duty
- Intermittent current at 30% duty (uninterrupted)
- 455A uninterrupted at 30% duty
- Intermittent current at 40% duty (interrupted)
- 395A interrupted at 40% duty
- Intermittent current at 40% duty (uninterrupted)
- 395A uninterrupted at 40% duty
- Intermittent current at 50% duty (interrupted)
- 355A interrupted at 50% duty
- Intermittent current at 50% duty (uninterrupted)
- 355A uninterrupted at 50% duty
- Intermittent current at 60% duty (interrupted)
- 325A interrupted at 60% duty
- Intermittent current at 60% duty (uninterrupted)
- 325A uninterrupted at 60% duty
- Intermittent current at 70% duty (interrupted)
- 300A interrupted at 70% duty
- Intermittent current at 70% duty (uninterrupted)
- 300A uninterrupted at 70% duty
- Fault breaking capacity at 5 ms, with blowouts
- 1500A at 96V D.C.
“(In accordance with UL583*) Blowouts 1500A at 96V D.C. No Blowouts 1500A at 48V D.C.”
Source: albrightinternational.com/products/sw202
“30% Duty 455A 455A”
Source: albrightinternational.com/products/sw202
“30% Duty 455A 455A”
Source: albrightinternational.com/products/sw202
“40% Duty 395A 395A”
Source: albrightinternational.com/products/sw202
“40% Duty 395A 395A”
Source: albrightinternational.com/products/sw202
“50% Duty 355A 355A”
Source: albrightinternational.com/products/sw202
“50% Duty 355A 355A”
Source: albrightinternational.com/products/sw202
“60% Duty 325A 325A”
Source: albrightinternational.com/products/sw202
“60% Duty 325A 325A”
Source: albrightinternational.com/products/sw202
“70% Duty 300A 300A”
Source: albrightinternational.com/products/sw202
“70% Duty 300A 300A”
Source: albrightinternational.com/products/sw202
“(In accordance with UL583*) Blowouts 1500A at 96V D.C. No Blowouts 1500A at 48V D.C.”
Source: albrightinternational.com/products/sw202
Compatibility
- What the maker says it is for
- motors as used on electric vehicles, such as industrial trucks and airport
“originally for motors as used on electric vehicles, such as industrial trucks and airport tractors”
Source: albrightinternational.com/products/sw202
Frame and components
- Part type
- D.C. contactor
“SW202 D.C. contactor for motor reversing - Albright”
Source: albrightinternational.com/products/sw202
Identity
- Manufacturer of record
- Albright
- Model code
- SW202
“SW202 D.C. contactor for motor reversing - Albright”
Source: albrightinternational.com/products/sw202
“SW202 D.C. contactor for motor reversing - Albright”
Source: albrightinternational.com/products/sw202
Other findings
- Coil connections
- 6.3mm spade coil connections
- Coil voltage range
- 6 - 240V (rectifier board required for A.C.)
- Contact arrangement
- single pole double throw, double breaking main contacts with silver alloy tips
- Failsafe
- if both coils are energised simultaneously the contact arrangement is open
- Main terminals
- M10 stud main terminals
- Max contact voltage no blowouts interrupted
- 48V
- Max contact voltage with blowouts interrupted
- 96V
- Mechanical durability
- > 5,000,000 Cycles
- Thermal current rating interrupted
- 250A interrupted
- Thermal current rating uninterrupted
- 250A uninterrupted
- Voltage drop per pole
- 40mV at 250A
“The SW202 has M10 stud main terminals and 6.3mm spade coil connections.”
Source: albrightinternational.com/products/sw202
“Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V”
Source: albrightinternational.com/products/sw202
“The SW202 features single pole double throw, double breaking main contacts with silver alloy tips”
Source: albrightinternational.com/products/sw202
“if both coils are energised simultaneously the contact arrangement is open circuit”
Source: albrightinternational.com/products/sw202
“The SW202 has M10 stud main terminals and 6.3mm spade coil connections.”
Source: albrightinternational.com/products/sw202
“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”
Source: albrightinternational.com/products/sw202
“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”
Source: albrightinternational.com/products/sw202
“Mechanical Durability > 5,000,000 Cycles”
Source: albrightinternational.com/products/sw202
“Thermal Current Rating 250A 250A”
Source: albrightinternational.com/products/sw202
“Thermal Current Rating 250A 250A”
Source: albrightinternational.com/products/sw202
“Typical Voltage Drop per pole across New Contacts at 250A 40mV”
Source: albrightinternational.com/products/sw202
Sources
- SW202 D.C. contactor for motor reversing - AlbrightArchived document
Source: albrightinternational.com/products/sw202
Retrieved October 2, 2026