Albright International SW202

Albright International's product page

Identity

Type
Solenoid
Maker printed on the part
Albright International
Maker part number
SW202

Motor and performance

Fault breaking capacity at 5 ms, no blowouts
1500A at 48V D.C.

“(In accordance with UL583*) Blowouts 1500A at 96V D.C. No Blowouts 1500A at 48V D.C.”

Source: albrightinternational.com/products/sw202

Intermittent current at 30% duty (interrupted)
455A interrupted at 30% duty

“30% Duty 455A 455A”

Source: albrightinternational.com/products/sw202

Intermittent current at 30% duty (uninterrupted)
455A uninterrupted at 30% duty

“30% Duty 455A 455A”

Source: albrightinternational.com/products/sw202

Intermittent current at 40% duty (interrupted)
395A interrupted at 40% duty

“40% Duty 395A 395A”

Source: albrightinternational.com/products/sw202

Intermittent current at 40% duty (uninterrupted)
395A uninterrupted at 40% duty

“40% Duty 395A 395A”

Source: albrightinternational.com/products/sw202

Intermittent current at 50% duty (interrupted)
355A interrupted at 50% duty

“50% Duty 355A 355A”

Source: albrightinternational.com/products/sw202

Intermittent current at 50% duty (uninterrupted)
355A uninterrupted at 50% duty

“50% Duty 355A 355A”

Source: albrightinternational.com/products/sw202

Intermittent current at 60% duty (interrupted)
325A interrupted at 60% duty

“60% Duty 325A 325A”

Source: albrightinternational.com/products/sw202

Intermittent current at 60% duty (uninterrupted)
325A uninterrupted at 60% duty

“60% Duty 325A 325A”

Source: albrightinternational.com/products/sw202

Intermittent current at 70% duty (interrupted)
300A interrupted at 70% duty

“70% Duty 300A 300A”

Source: albrightinternational.com/products/sw202

Intermittent current at 70% duty (uninterrupted)
300A uninterrupted at 70% duty

“70% Duty 300A 300A”

Source: albrightinternational.com/products/sw202

Fault breaking capacity at 5 ms, with blowouts
1500A at 96V D.C.

“(In accordance with UL583*) Blowouts 1500A at 96V D.C. No Blowouts 1500A at 48V D.C.”

Source: albrightinternational.com/products/sw202

Compatibility

What the maker says it is for
motors as used on electric vehicles, such as industrial trucks and airport

“originally for motors as used on electric vehicles, such as industrial trucks and airport tractors”

Source: albrightinternational.com/products/sw202

Frame and components

Part type
D.C. contactor

“SW202 D.C. contactor for motor reversing - Albright”

Source: albrightinternational.com/products/sw202

Identity

Manufacturer of record
Albright

“SW202 D.C. contactor for motor reversing - Albright”

Source: albrightinternational.com/products/sw202

Model code
SW202

“SW202 D.C. contactor for motor reversing - Albright”

Source: albrightinternational.com/products/sw202

Other findings

Coil connections
6.3mm spade coil connections

“The SW202 has M10 stud main terminals and 6.3mm spade coil connections.”

Source: albrightinternational.com/products/sw202

Coil voltage range
6 - 240V (rectifier board required for A.C.)

“Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V”

Source: albrightinternational.com/products/sw202

Contact arrangement
single pole double throw, double breaking main contacts with silver alloy tips

“The SW202 features single pole double throw, double breaking main contacts with silver alloy tips”

Source: albrightinternational.com/products/sw202

Failsafe
if both coils are energised simultaneously the contact arrangement is open

“if both coils are energised simultaneously the contact arrangement is open circuit”

Source: albrightinternational.com/products/sw202

Main terminals
M10 stud main terminals

“The SW202 has M10 stud main terminals and 6.3mm spade coil connections.”

Source: albrightinternational.com/products/sw202

Max contact voltage no blowouts interrupted
48V

“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”

Source: albrightinternational.com/products/sw202

Max contact voltage with blowouts interrupted
96V

“Maximum Recommended Contact Voltages Blowouts 96V - No Blowouts 48V -”

Source: albrightinternational.com/products/sw202

Mechanical durability
> 5,000,000 Cycles

“Mechanical Durability > 5,000,000 Cycles”

Source: albrightinternational.com/products/sw202

Thermal current rating interrupted
250A interrupted

“Thermal Current Rating 250A 250A”

Source: albrightinternational.com/products/sw202

Thermal current rating uninterrupted
250A uninterrupted

“Thermal Current Rating 250A 250A”

Source: albrightinternational.com/products/sw202

Voltage drop per pole
40mV at 250A

“Typical Voltage Drop per pole across New Contacts at 250A 40mV”

Source: albrightinternational.com/products/sw202

Sources

  • SW202 D.C. contactor for motor reversing - AlbrightArchived document

    Source: albrightinternational.com/products/sw202

    Retrieved October 2, 2026