Skip to content

Albright International SW80

Albright International's product page

Identity

Type
Solenoid
Maker printed on the part
Albright International
Maker part number
SW80

Motor and performance

Intermittent current at 30% duty (interrupted)
185A interrupted at 30% duty

“30% Duty 185A 230A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 30% duty (uninterrupted)
230A uninterrupted at 30% duty

“30% Duty 185A 230A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 40% duty (interrupted)
160A interrupted at 40% duty

“40% Duty 160A 200A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 40% duty (uninterrupted)
200A uninterrupted at 40% duty

“40% Duty 160A 200A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 50% duty (interrupted)
140A interrupted at 50% duty

“50% Duty 140A 175A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 50% duty (uninterrupted)
175A uninterrupted at 50% duty

“50% Duty 140A 175A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 60% duty (interrupted)
130A interrupted at 60% duty

“60% Duty 130A 160A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 60% duty (uninterrupted)
160A uninterrupted at 60% duty

“60% Duty 130A 160A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 70% duty (interrupted)
120A interrupted at 70% duty

“70% Duty 120A 150A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Intermittent current at 70% duty (uninterrupted)
150A uninterrupted at 70% duty

“70% Duty 120A 150A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Auxiliary contact switching at 24 volts
5A at 24V D.C. (column not attributed)

“5A at 24V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Auxiliary contact switching at 48 volts
2A at 48V D.C. (column not attributed)

“2A at 48V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Auxiliary contact switching at 240 volts
0.5A at 240V D.C. (column not attributed)

“0.5A at 240V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Battery and charging

SW80 rated fault current breaking capacity, 5 ms (UL 583)
600A at 48V

“SW80 600A at 48V”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

SW80B rated fault current breaking capacity, 5 ms (UL 583)
600A at 96V

“SW80B 600A at 96V”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

SW80 rated fault current breaking capacity, resistive load (UL 508)
190A at 60V D.C.

“SW80 190A at 60V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

SW80B rated fault current breaking capacity, resistive load (UL 508)
190A at 96V D.C.

“SW80B 190A at 96V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

SW80 maximum recommended contact voltage, interrupted
48V D.C.

“SW80 48V D.C. 60V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

SW80 maximum recommended contact voltage, uninterrupted
60V D.C.

“SW80 48V D.C. 60V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

SW80B maximum recommended contact voltage
96V D.C.

“SW80B 96V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Compatibility

What the maker says it is for
motors as used on electric vehicles such as industrial trucks, and telecom

“including motors as used on electric vehicles such as industrial trucks, and telecom and power distribution applications.”

Source: albrightinternational.com/products/sw80

Frame and components

Part type
D.C. contactor

“SW80 D.C. contactor - Albright”

Source: albrightinternational.com/products/sw80

Identity

Manufacturer of record
Albright

“SW80 D.C. contactor - Albright”

Source: albrightinternational.com/products/sw80

Model code
SW80

“SW80 D.C. contactor - Albright”

Source: albrightinternational.com/products/sw80

Other findings

Advised busbar size
80mm2

“Copper busbar 80mm2 [0.124inch2 ]”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Auxiliary thermal current rating
5A

“Auxiliary Thermal Current Rating 5A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Coil power dissipation continuously
7 - 13 Watts

“Continuously Rated Types 7 - 13 Watts”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Coil power dissipation highly
20 - 30 Watts

“Highly Intermittent Rated Types 20 - 30 Watts”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Coil power dissipation intermittently
15 - 20 Watts

“Intermittently Rated types 15 - 20 Watts”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Coil power dissipation prolonged
13 - 15 Watts

“Prolonged Rated Types 13 - 15 Watts”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Coil voltage range
6 to 240V D.C. (rectifier board for A.C.)

“Coil Voltage Available (Us) (Rectifier board required for A.C.) From 6 to 240V D.C.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Drop out voltage range
10 - 25% Us

“Drop-Out Voltage Range 10 - 25% Us”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Form
NO - SP - ST

“SW80 NO - SP - ST”

Source: albrightinternational.com/products/sw80

Guideline weight
350 gms

“SW80 350 gms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Guideline weight with auxiliary
+ 20 gms

“With Auxiliary + 20 gms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Guideline weight with blowouts
+ 50 gms

“With Blowouts + 50 gms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Main terminals
M8 stud main terminals

“The SW80 has M8 stud main terminals and 6.3mm spade coil connections.”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Max pull in voltage continuously
66% Us

“(100% Duty Cycle) 66% Us”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Max pull in voltage highly
60% Us

“(Max 25% Duty Cycle) 60% Us”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Max pull in voltage intermittently
60% Us

“(Max 70% Duty Cycle) 60% Us”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Max pull in voltage prolonged
60% Us

“(Max 90% Duty Cycle) 60% Us”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Mechanical durability
> 5,000,000 Cycles

“Mechanical Durability > 5,000,000 Cycles”

Source: albrightinternational.com/products/sw80

Mounting tapped holes
M4 tapped holes or mounting brackets

“Mounting is via M4 tapped holes or mounting brackets”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Operating ambient temperature
- 40˚C to + 60˚C

“Operating Ambient Temperature - 40˚C to + 60˚C”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Thermal current rating interrupted
100A interrupted

“Thermal Current Rating (I th) 100A 125A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Thermal current rating uninterrupted
125A uninterrupted

“Thermal Current Rating (I th) 100A 125A”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Typical contact bounce period
3ms

“Typical Contact Bounce Period 3ms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Typical drop out time with diode
50ms

“With Diode Suppression 50ms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Typical drop out time with diode and resistor
8 - 20ms

“(Subject to resistance value) 8 - 20ms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Typical drop out time without suppression
5ms

“Without Suppression 5ms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Typical pull in time
20ms

“Typical Pull-In Time 20ms”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Voltage drop per pole
40mV at 100A

“Typical Voltage Drop per pole across New Contacts at 100A 40mV”

Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

Sources

  • Archived document

    Source: albrightinternational.com/wpcms/wp-content/uploads/2020/08/SW80-JPT-Connector-Data-Sheet.pdf

    Retrieved October 2, 2026

  • SW80 D.C. contactor - AlbrightArchived document

    Source: albrightinternational.com/products/sw80

    Retrieved October 2, 2026