Product Recall: RELiON Battery Insight Series 48V 30aH (2303-0032)
The notice identifies it by: Model Number: 48V030-GC2; Affected Serial Number Ranges: RB48300020210314057- RB48300020210314729, RB48300020210330001- RB48300020210330715, and RB48300020210507012-RB48300020221016550. The serial number of the recalled product can be found on the side of the battery.
Manufacturer: RELiON
- Hazard
The product has been identified as presenting a serious risk of fire as a manufacturing fault can lead to corrosion across the ribbon cable terminal where it mates with the Printed Circuit Board (PCB) for the Battery Management System. Stress on the product’s capacitor can lead to the sealing mechanism becoming compromised, which can cause electrolytes to leak onto the PCB. If there is arcing across the sense ribbon terminal, the resistors can overheat, and the product can ignite. The product does not meet the requirements of the General Product Safety Regulations 2005.
- What to do
Consumers should immediately stop using the RELiON InSight Series 48V battery if it is included within the recalled serial numbers and contact RELiON to coordinate a return. For further information, please access the RELiON website at: https://relionbattery.com/product-recall-eu.
- Description
The intended use includes, but is not limited to, golf carts, low-speed vehicles, automated guided vehicles (AGVs), and outdoor utility terrain vehicles (UTVs). The batteries can be utilised as stand-alone units or connected in an approved parallel architecture to increase capacity.
- Recall date
- March 14, 2023
Affected products in our database
- InSight GC2 48VEXACT MATCH
Regulator & source
Office for Product Safety and Standards (OPSS) · gov.uk/government/organisations/office-for-product-safety-and-standards
Official recall notice: gov.uk/product-safety-alerts-reports-recalls/product-recall-relion-battery-insight-series-48v-30ah-2303-0032