What we found
- Documented by its manufacturer to fit the carts listed below across several brands.
- Specifications are published for it, each with its source, 3 of them corroborated by a second source.
- 5 figures are contradicted by another credible source. Both readings are shown below, and neither is presented as the correct one.
Battery and charging
- Working voltage range
- 43.2 - 58.4V
- Voltage range the maker recommends
- 48.0V - 57.0V
- Maximum charge current
- 350A
- Permitted charger
- Only Bolt's own charger
- Round-trip efficiency
- 0.99
- Rated charge cycles
- 2500 cycles at 1C, or 4000 at 0.2C
- Case material
- Powder Coated Steel
- Cell arrangement
- Sixteen cells in series
- Reserve capacity
- 252 minutes at 25 A
- Energy stated by the maker
- 5,376 Wh
- Nominal capacity
- 60 Ah
- Nominal voltage
- 51.2 V
- Cell chemistry
- Prismatic- LiFePO4
- Continuous discharge
250A
48-volt-60-ah-standard-kit-fleet · retrieved 15 September 2026
“Maximum Continuous Discharge Current 250A”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
185 A
BE6051F-Universal-Installation-Instruction.pdf · retrieved 16 September 2026
“7 Continuous discharge current 185A 8 Peak discharge current 400A(3 Secs)”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
- Peak discharge
520A ± 15.6A (30S)
48-volt-60-ah-standard-kit-fleet · retrieved 15 September 2026
“Peak Discharge Current 520A ± 15.6A (30S)”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
400 A for 3 seconds
BE6051F-Universal-Installation-Instruction.pdf · retrieved 16 September 2026
“8 Peak discharge current 400A(3 Secs) 9 Total weight 72.75 LBS”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
- Recommended charge current
5 - 52A
48-volt-60-ah-standard-kit-fleet · retrieved 15 September 2026
“Recommended Charge Current 5 - 52A”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
60 A normal charge
BE6051F-Universal-Installation-Instruction.pdf · retrieved 16 September 2026
“5 Charge current Normal 60A Max cut-off current 200A 6 Cut-off voltage 40V”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
- Discharge cut-off
- 40 V
- Charge cut-off
- 58.5V
- Maximum in parallel
- Two, at most
“Working Voltage 43.2 - 58.4V”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“Recommended Voltage 48.0V - 57.0V”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“Maximum Input Current 350A”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“ONLY use the charger provided by Bolt Energy USA when charging. Check the voltage of Battery and relevant connectors before using.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Efficiency 0.99”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
Unconfirmed
“13 Cycle life 1C@DOD100% ≥2500 cycles 0.2C@DOD100% ≥4000 cycles”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Case Material Powder Coated Steel”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“2 Standard voltage 51.2V(16S) 3 Standard Charge voltage 58.4 V”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Cell Configuration 1P16S”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“Capacity @ 25A 252 min”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“Energy 5,376Wh”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“1 Rated capacity 60Ah 2 Standard voltage 51.2V(16S)”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Nominal Capacity 60Ah”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“Nominal Voltage 51.2V”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“Cell Type - Chemistry Prismatic- LiFePO4”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
The maker’s own documents give different figures
The maker’s own documents give different figures
The maker’s own documents give different figures
“6 Cut-off voltage 40V 7 Continuous discharge current 185A”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“BMS Charge Voltage Cut-Off 58.5V”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“1) Please ensure two batteries are same Model Bolt Energy batteries and do not parallel with other brand batteries. 2) Maximum 2 packs of batteries connect in parallel.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
Battery care and safety
- Self-discharge rate
- 3% a month or less
- Where the BMS cuts out on current
- 260 A ± 7.8 A (50S) 520A ± 15.6A (30S)
- Where the BMS cuts out on charge current
375A
48-volt-60-ah-standard-kit-fleet · retrieved 15 September 2026
“Charge Current Cut-Off 375A”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
200 A, and then it cuts off
BE6051F-Universal-Installation-Instruction.pdf · retrieved 16 September 2026
“5 Charge current Normal 60A Max cut-off current 200A 6 Cut-off voltage 40V”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
- Voltage charging resumes at
- <58.5V
- Storage temperature
- 50 to 113 °F, at 75% humidity or less
- Charge temperature range
34°F to 140°F (0-60°C)
48-volt-60-ah-standard-kit-fleet · retrieved 15 September 2026
“Charging Temp. Range 34°F to 140°F (0-60°C)”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
30 to 140 °F
BE6051F-Universal-Installation-Instruction.pdf · retrieved 16 September 2026
“11 Charge method Charge 30 - 140°F Discharge -4 - 140°F”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
- Discharge temperature range
- −4 to 140 °F
“14 Self-discharge rate ≤3%/Month”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Self Discharge <3% per Month”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“BMS Discharge Current Cut-Off 260 A ± A7.8A (50S) 520A ± 15.6A (30S)”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
The maker’s own documents give different figures
“Reconnect Voltage <58.5V”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
Unconfirmed
“12 Storage environment Temperature 50 - 113°F Humidity ≤ 75%RH”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
The maker’s own documents give different figures
“11 Charge method Charge 30 - 140°F Discharge -4 - 140°F”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
Size and fit
- Overall dimensions
- 12.80 × 12.01 × 10.28 in
- Stated weight
- 72.75 lb
- Terminal torque
- 132 in-lb, and no more
“15 Battery dimension L= 12.80 IN W= 12.01IN H= 10.28 IN”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“9 Total weight 72.75 LBS 10 Impedance at 1000Hz. ≤50mΩ”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Install your positive and negative battery and charger cables (red to positive, black to negative) Using a torque wrench, tighten to 132 inch lbs. (11ft lbs).DO NOT OVER TIGHTEN!”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
Compatibility
- What the CAN port is for
- CAN port for testing battery
“CAN CAN port for testing battery”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
Frame and components
- Enclosure rating
- Designed with IP66 standard
“Enclosure Protection Designed with IP66 Stardard”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
Identity
- Model code
- BE6051F
“WARNING: THIS SPECIFIC BOLT BATTERY IS DESIGNED AND TESTED FOR STOCK UN-MODIFIED GOLF CARTS ONLY Model: BE6051F Bolt Energy USA LLC”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
Other findings
- Bluetooth
- Bluetooth receiver
- Auto sleep after inactivity
- Sleeps after 12 hours; hold the button 2 seconds to wake
- Bluetooth monitoring
- “Bolt USA” app: voltage and state of charge
- Capacity retained at temperature
- 70% at −20 °C, 85% at freezing, measured at 1C
- Charger extension cord limit
- No cord over 15 ft, and nothing lighter than 12 AWG
- Charge storage retention
- At least 97% left after a month in storage
- Charging method
- Constant current, then constant voltage
- Intended use restriction
- Stock, unmodified golf carts only
- Internal impedance
- 50 mΩ or less, at 50% charge
- Manufacturer denies series connection
- Never in series — it voids the warranty
- Opportunity charging
- Partial charges are fine, if it reaches 100% once a day
- Professional kit contents
- Pack, SOC meter, 30 A reducer, 400 A solenoid, 2 AWG cables, charger, cord
- Standard charge voltage
- 58.4 V
- Storage state of charge
- 50–80% charged, charger off, battery switched off
“Bluetooth Bluetooth receiver”
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
“Your battery features an auto-sleep function that activates after 12 hours of inactivity. To wake it, simply use one of the two on/off buttons mentioned above.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“In the APP store install “Bolt USA” You will be able to read the voltage, SOC, etc. after connected properly.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“5 Discharge temperature characteristic At 1.0C -4°F(-20℃) ≥70% 14°F(-10℃) ≥80% 32°F(0℃) ≥85% 77°F(25℃) ≥100% 113°F(45℃) ≥95% Discharge Capacity at specified temperature/Capacity at 77°F”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Do not use an extension cord over 15ft long with a rating below 12AWG. Longer cords with lighter gauge wire will cause heat resistance, increasing the risk of an electrical fire.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“2 Charging storage ability in normal temperature Rest Capacity ≥ Standard Capacity *97% After standard charging, store at 77°F ± 41°F for 1 month, and then discharge capacity @0.2C current to the end of discharge voltage, then measure the capacity of cell.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“4 Charging method CC-CV 5 Charge current Normal 60A Max cut-off current 200A”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“WARNING: THIS SPECIFIC BOLT BATTERY IS DESIGNED AND TESTED FOR STOCK UN-MODIFIED GOLF CARTS ONLY Model: BE6051F”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“4 Internal Impedance ≤50mΩ At 50% SOC, 1kHz AC internal resistance test instrument.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Never run Batteries in series. If you do, your warranty will be VOID. Two of our Batteries in parallel will work and we recommend you seek proper installation guidance from Bolt Energy USA.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“Opportunity charging (partial charges below 100%) or interrupting a charge is acceptable with lithium batteries, provided the battery completes a full 100% charge cycle at least once a day.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“51V60AH Complete professional kit.(BE6051F) Note: Standard kit will only have some of these products. 51V-60AH Battery SOC (state of charge meter) 36-51V BOLT 30 AMP high output reducer *2-5/16 battery post with lock washers *User manual * 3- 3/8 ,3-5/16 battery ring terminal *3-ABC stickers *1-Bolt oval sticker *1-Bolt Lightning sticker *10-10" tie straps Bracket with Nuts and bolts 2-40" 2AWG cables Lead battery removal strap 48V- 400A solenoid with diode Waterproof charger 12 AWG 15 foot extension cord Deco Plate for AC Hardwire AC Hardwire onboard charge adaptor”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
“3 Standard Charge voltage 58.4 V 4 Charging method CC-CV”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
Unconfirmed
“If your vehicle will remain idle for a week or more, charge the battery to 50-80%, disconnect the charger, and turn off the battery by holding the on/off button (located on the battery) or the black button on the SOC display for 3 seconds.”
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
Compatible carts
Only as Bolt's own compatibility search answers it for the Club Car Onward, which Bolt name as a model rather than by this trim — check yours before buying. — applies to Club Car Onward 2 Passenger, Club Car Onward 4 Passenger, Club Car Onward 6 Passenger
Sources do not establish: Tray fit and wiring as installed. Bolt's search answers by make and model; their kits ship with cart-specific harnesses, and which harness a particular cart takes is the kit's own question.
Applies to Club Car Onward 2 Passenger, Club Car Onward 4 Passenger, Club Car Onward 6 Passenger
Sources do not establish: Bolt's search answers only "Compatible" for this kit. Bolt's own fitment guide lists a cart-specific harness and firmware for the kits it covers on this cart, and does not say whether this kit needs them.
Applies to Club Car Tempo, E-Z-GO TXT
Source: boltenergyusa.com/bolt-cart-compatibility-search
- Club Car DSManufacturer documentedView cart: Club Car DS →View battery: Club Car DS →
- Club Car PrecedentManufacturer documentedView cart: Club Car Precedent →View battery: Club Car Precedent →
- Club Car TempoManufacturer documentedView cart: Club Car Tempo →View battery: Club Car Tempo →
- E-Z-GO TXTManufacturer documentedView cart: E-Z-GO TXT →View battery: E-Z-GO TXT →
Sources
- Bolt Energy USA — 51.2 Volt 60AH (Fleet)Manufacturer battery page
Bolt Energy USA
Source: boltenergyusa.com/product/48-volt-60-ah-standard-kit-fleet
Retrieved September 15, 2026
- Bolt Energy USA — Cart Compatibility SearchManufacturer document
Bolt Energy USA
Source: boltenergyusa.com/bolt-cart-compatibility-search
Retrieved September 16, 2026
- Bolt Energy USA — BE 6051F Universal Installation InstructionManufacturer document
Bolt Energy USA
Source: boltenergyusa.com/wp-content/uploads/2026/08/BE6051F-Universal-Installation-Instruction.pdf
Retrieved September 16, 2026